- 12 channel interpretive ECG for adult, pediatric and neonatal use
– over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)
– memory for up to 200 patients
– real-time preview monitor
– PC compatible through LAN or Wi-Fi
– multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
– lead fault message
– pace maker detection
– automatic arrhythmia detection
– 3, 5, 10 minutes long term recording
– grid function allows you to use low cost plain fax paper
– wide and clear colour 7” TFT LCD (800×480)
– touch screen for easy operation
– full disclosure function
Technical Specifications
• ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition
• Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg
• Recording channel: 3 channels 1 rhythm, 3 channels 3 rhythm, 6 channels 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report
• Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV
• Printing speed: 5, 12.5, 25, 50, 100 mm/s
• Sampling rate: 2,000 samples/sec
• Filters: AC (50/60 Hz, -20 dB or better)
• Muscle (25~35 Hz, -3dB or better)
• Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better)
• Low pass filter: off, 40 Hz, 100 Hz, 150 Hz
• Display: 7″ color TFT LCD display (800×480), 12 channels preview ECG wave
• Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead
• User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu)
• Patient data: ID, name, age, sex, height, weight, smoke, race
• Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis
• Recorder: Thermal print head, roll paper, A4 report paper: 210×300 mm (8.5″x11″)
• Resolution:
– Vertical: 8 dot/mm
– Horizontal: 16 dot/mm
• Electrical:
– Internal noise: 20 µV (p-p) max
– Input circuit: floating input
– Input impedance: =50 MO
– Input voltage range: = ±5 mV
– Common mode rejection: > 105 dB
– DC offset voltage: = ±400 mV
– Time constant: 3.2 sec
– Patient leakage current: < 10 µA
– Frequency response: 0.05 ~150 Hz
– Isolated and defibrillation protected
• Signal quality control: Disconnected lead detection, Pacemaker pulse detection
• ECG data storage: storage for 200 ECGs (Internal on flash memory)
• Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max
• Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts)
• Communication: PC connection with LAN D2 Wi-Fi
• Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC
Standard accessories
• Patient cable – 10 leads
• LAN cable
• 1 bottle of ECG cream (70 g)
• 1 power cable
• manual (GB, IT)
• 1 paper roll
• 4 limb electrodes
• 6 chest limb electrodes
• EKG View Plus (GB, IT)